In use, the funnel is held vertically with the end of the tube closed by a finger. The liquid to be measured is poured through the mesh to remove any particles which might block the tube. When the fluid level reaches the mesh, the amount inside is equal to the rated volume. To take the measurement, the finger is released as a stopclock is started, and the liquid is allowed to run into a measuring container. The time in seconds is recorded as a measure of the viscosity.
In American practice (and most of the oil industry) the volume collected is a quart. If water is used, the time should be 26 +/- 0.5 seconds. If the time is less than this the tube is probably enlarged by erosion, if more it may be blocked or damaged, and the funnel should be replaced. In some companies, and Europe in particular, the volume collected is a litre, for which the water funnel time should be 28 seconds. Marsh himself collected 0.50 litre, for which the time was 18.5 seconds.
The Marsh funnel time is often referred to as the Marsh funnel viscosity, and represented by the abbreviation FV. The unit (seconds) is often omitted. Formally, the volume should also be stated.
The (quart) Marsh funnel time for typical drilling muds is 34 to 50 seconds, though mud mixtures to cope with some geological conditions may have a time of 100 or more seconds.A. W. McCray & F. W. Cole (1979) Oil Well Drilling Technology University of Oklahoma Press
While the most common use is for , which are non-Newtonian fluids, the Marsh funnel is not a rheometer, because it only provides one measurement under one flow condition. However the effective viscosity can be determined from following simple formula.M. J. Pitt (2000) SPE Drilling and Completion vol 15 no1 pages 3-6 “The Marsh Funnel and Drilling Fluid Viscosity: A New Equation for Field Use”
μ = ρ (t - 25)
where μ = effective viscosity in centipoise
For example, a mud of funnel time 40 seconds and density 1.1 g/cm3 has an effective viscosity of about 16.5 cP. For the range of times of typical muds above, the shear rate in the Marsh funnel is about 2000 s−1.
ρ = density in g/cm3
t = quart funnel time in seconds
Other Flow Cones
Further reading
|
|